P989E 0-999 Two Trigger time period - Default 60 seconds
CHIME ALARM TO KEYPAD BUZZER TIMES - P991E to P994E
If a Chime alarm is generated, this time will set how long the keypad buzzer will sound before resetting. Chime zones
are configured at option 8 (P411E-P430E) or option 4 (P431E-P450E). The time value is in 1/10th seconds.
P991E 1-999 Area "A" Chime Zone Alarm to keypad buzzer duration - Default 20 (2 seconds)
P992E 1-999 Area "B" Chime Zone Alarm to keypad buzzer duration - Default 20 (2 seconds)
P993E 1-999 Area "C" Chime Zone Alarm to keypad buzzer duration - Default 20 (2 seconds)
P994E 1-999 Area "D" Chime Zone Alarm to keypad buzzer duration - Default 20 (2 seconds)
CHIME ALARM TO OUTPUT TIMES - P995E to P998E
If a Chime alarm is generated, this time will set how long an output will turn on before resetting. The time value is in
1/10th seconds.
P995E 1-999 Area "A" Chime Zone Alarm to Output duration - Default 20 (2 seconds)
P996E 1-999 Area "B" Chime Zone Alarm to Output duration - Default 20 (2 seconds)
P997E 1-999 Area "C" Chime Zone Alarm to Output duration - Default 20 (2 seconds)
P998E 1-999 Area "D" Chime Zone Alarm to Output duration - Default 20 (2 seconds)
PROGRAMMING REAL TIME CLOCK AND TIME ZONES
PROGRAMMING REAL TIME CLOCK AND TIME ZONESPROGRAMMING REAL TIME CLOCK AND TIME ZONES
PROGRAMMING REAL TIME CLOCK AND TIME ZONES
SETTING THE REAL TIME CLOCK - P818E - P822E
These addresses are used to set the internal clock used by the time zone functions, time & date stamping of events
in the event buffer and the time for any automatic test calls to a monitoring station.
P818E 1-7 Set day of the week - where values of 1-7 represent Sunday to Saturday (Sunday = 1)
P819E 0000 - 2359 Set time - Use 24 hour format
P820E 1-31 Set day of the month - where values of 1-31 represent days in the month.
P821E 1-12 Set Month - where values of 1-12 represent the month.
P822E 0-99 Set Year - Where 0-99 represent years, i.e. 5 = 2005.
PROGRAMMING DAYLIGHT SAVING ADJUSTMENTS - P823E - P829E
As the panel has a real time clock, provision has been made for automatic adjustments for daylight saving. These
addresses provide the panel with the information required to perform the daylight saving adjustments.
P823E 0-5 Daylight Saving Start Sunday - This is the Sunday number in the month that daylight saving will
begin (values of 1-5 are allowed). Default = 1
P824E 0-12 Daylight Saving Start Month - This is month in which the above Sunday will occur. (Values of 1-
12 are allowed). Default = 10
P825E 0-24 Daylight Saving Start Hour - This is the hour that daylight savings will begin (values of 0-24 are
allowed). Default = 2
P826E 0-5 Daylight Saving End Sunday - This is the Sunday number in the month that daylight savings will
end (values of 1-5 are allowed). Default = 3
P827E 0-12 Daylight Saving End Month - This is the month in which the Sunday number will occur (values of
1-12 are allowed). Default = 3
P828E 0-24 Daylight Saving End Hour - This is the hour that daylight savings will end (values of 0-24 are
allowed. Default = 3
P829E 8 Daylight Saving Active - If you enter this address and 8 is on, this means that the panel is
currently observing daylight saving time. If 8 is turned off, daylight saving is not active. When
setting up a panel for the first time (or after re-powering the panel), if daylight saving should be
active you must turn on 8 at this location to tell the panel that daylight saving time is active.