P372E Zone 32 option Group # 1-20 - default 0 P404E Zone 64 option Group # 1-20 - default 0
ZONE GROUP OPTIONS A - ARM/DISARM
Zone Options A
P411E Zone Group #1 Options A Default 1,6,7 1 = Assigned to Area “A”
P412E Zone Group #2 Options A Default 1,6,7 2 = Assigned to Area “B”
P413E Zone Group #3 Options A Default 1,6,7 3 = Assigned to Area “C”
P414E Zone Group #4 Options A Default 1,6,7 4 = Assigned to Area “D”
P415E Zone Group #5 Options A Default 1,6,7 5 = Is a Stay Mode Zone
P416E Zone Group #6 Options A Default 1,6,7 6 = Can be Manually Bypassed
P417E Zone Group #7 Options A Default 1,6,7 7 = Can Auto-bypass
P418E Zone Group #8 Options A Default 1,6,7 8 = Is a Chime Zone
P419E Zone Group #9 Options A Default 1,6,7
P420E Zone Group #10 Options A Default 1,6,7
P421E Zone Group #11 Options A Default 1,6,7
P422E Zone Group #12 Options A Default 1,6,7
P423E Zone Group #13 Options A Default 1,6,7
P424E Zone Group #14 Options A Default 1,6,7
P425E Zone Group #15 Options A Default 1,6,7
P426E Zone Group #16 Options A Default 1,6,7
P427E Zone Group #17 Options A Default 1,6,7
P428E Zone Group #18 Options A Default 1,6,7
P429E Zone Group #19 Options A Default 1,6,7
P430E Zone Group #20 Options A Default 1,6,7
Option 1 Assigned to Area “A”- A zone with this option turned on is in Area A. If in more than one area, all areas
assigned to the zone must be armed before it is in the armed state.
Option 2 Assigned to Area “B”- A zone with this option turned on is in Area B. If in more than one area, all areas
assigned to the zone must be armed before it is in the armed state.
Option 3 Assigned to Area “C”- A zone with this option turned on is in Area C. If in more than one area, all
areas assigned to the zone must be armed before it is in the armed state.
Option 4 Assigned to Area “D”- A zone with this option turned on is in Area D. If in more than one area, all
areas assigned to the zone must be armed before it is in the armed state.
Option 5 Is a Stay Mode Zone - A zone with this option turned on is a stay mode zone. If in more than one area,
all areas assigned to the zone must be in stay mode before it is in the armed state.
Option 6 Can be Manually Bypassed - A zone with this option turned on can be bypassed using the “Bypass”
function.
Option 7 Can be Auto-Bypassed - A zone with this option turned on can be automatically bypassed if unsealed
at the end of the exit delay time.
Option 8 Is a Chime Zone - A zone with this option turned on will cause a Chime alarm when triggered during the
Disarmed state.
ZONE GROUP OPTIONS B - ZONE TYPE
Zone Options B
P431E Zone Group #1 Options B Default 0 1 = Is a 24 Hour Zone
P432E Zone Group #2 Options B Default 0 2 = Is a 24 Hour Fire Zone
P433E Zone Group #3 Options B Default 0 3 = Is a 24 Hour Auto-Reset Zone
P434E Zone Group #4 Options B Default 0 4 = Is a Permanent Chime Zone
P435E Zone Group #5 Options B Default 0 5 = Is a Handover Zone
P436E Zone Group #6 Options B Default 0 6 = Is a two Trigger Zone
P437E Zone Group #7 Options B Default 0 7 = Can Arm if zone not “Ready
P438E Zone Group #8 Options B Default 0 8 = Is a Siren Lockout Zone
P439E Zone Group #9 Options B Default 0
P440E Zone Group #10 Options B Default 0
P441E Zone Group #11 Options B Default 0
P442E Zone Group #12 Options B Default 0
P443E Zone Group #13 Options B Default 0
P444E Zone Group #14 Options B Default 0