Page 24
INSTALLER CODE - P410E
This code is used to enter Installer Program mode either from Client Program mode or directly depending upon
options set. The default installer code is 000000. The Installer Code can only be changed from Installer Program
Mode. To change the Installer Code press P410E, (the existing code will be displayed at the keypad). Enter in the
new code then press the ENTER button. The new code will be displayed on the LCD.
The Installer Code may vary from 3-6 digits in length.
If the alarm is Disarmed, the Installer Code can gain access directly to Installer Program Mode provided Option 3 at
address P741E is on.
DURESS DIGIT - P744E
P744E 0-9 Duress Digit (Default 0) - A Duress Alarm is activated when the "Duress Digit" defined at this
address is prefixed to a valid user code. The resulting Duress Alarm will disarm the Area in the
normal way but it can also be programmed to operate an output and/or report a duress event via
the dialler. Duress digit values of 1-9 may be programmed at this address. If the value is set to
zero (0) the Duress function is disabled. A Duress alarm will be reset the next time the area is
armed then disarmed.
ZONE PROGRAMMING
ZONE PROGRAMMINGZONE PROGRAMMING
ZONE PROGRAMMING
Up to 64 zones can be connected to the panel. All zones can be programmed as hardwired or wireless zones. The
functions or characteristics of every zone are configured in one of 20 zone groups. If a zone has a value of “0”
programmed as it’s group number, that zone is disabled. By default the first 16 zones are enabled as hardwired
zones. Up to two expanders can be connected to the panel to cover the hardwired zones. Expander 1 covers zones
1-32 and expander 2 covers zones 33-64. If there are no hardwired zones assigned to an expander, the panel will not
expect the expander to be connected. If just one hardwired zone to be assigned to an expander the panel will then
expect to see the expander on the buss. If the expander is not there the panel will generate an expander failure alarm
until the expander is connected.
ASSIGNING A ZONE GROUP (1-20) TO A ZONE
P341E Zone 1 option Group # 1-20 - default 1 P373E Zone 33 option Group # 1-20 - default 0
P342E Zone 2 option Group # 1-20 - default 1 P374E Zone 34 option Group # 1-20 - default 0
P343E Zone 3 option Group # 1-20 - default 1 P375E Zone 35 option Group # 1-20 - default 0
P344E Zone 4 option Group # 1-20 - default 1 P376E Zone 36 option Group # 1-20 - default 0
P345E Zone 5 option Group # 1-20 - default 1 P377E Zone 37 option Group # 1-20 - default 0
P346E Zone 6 option Group # 1-20 - default 1 P378E Zone 38 option Group # 1-20 - default 0
P347E Zone 7 option Group # 1-20 - default 1 P379E Zone 39 option Group # 1-20 - default 0
P348E Zone 8 option Group # 1-20 - default 1 P380E Zone 40 option Group # 1-20 - default 0
P349E Zone 9 option Group # 1-20 - default 1 P381E Zone 41 option Group # 1-20 - default 0
P350E Zone 10 option Group # 1-20 - default 1 P382E Zone 42 option Group # 1-20 - default 0
P351E Zone 11 option Group # 1-20 - default 1 P383E Zone 43 option Group # 1-20 - default 0
P352E Zone 12 option Group # 1-20 - default 1 P384E Zone 44 option Group # 1-20 - default 0
P353E Zone 13 option Group # 1-20 - default 1 P385E Zone 45 option Group # 1-20 - default 0
P354E Zone 14 option Group # 1-20 - default 1 P386E Zone 46 option Group # 1-20 - default 0
P355E Zone 15 option Group # 1-20 - default 1 P387E Zone 47 option Group # 1-20 - default 0
P356E Zone 16 option Group # 1-20 - default 1 P388E Zone 48 option Group # 1-20 - default 0
P357E Zone 17 option Group # 1-20 - default 0 P389E Zone 49 option Group # 1-20 - default 0
P358E Zone 18 option Group # 1-20 - default 0 P390E Zone 50 option Group # 1-20 - default 0
P359E Zone 19 option Group # 1-20 - default 0 P391E Zone 51 option Group # 1-20 - default 0
P360E Zone 20 option Group # 1-20 - default 0 P392E Zone 52 option Group # 1-20 - default 0
P361E Zone 21 option Group # 1-20 - default 0 P393E Zone 53 option Group # 1-20 - default 0
P362E Zone 22 option Group # 1-20 - default 0 P394E Zone 54 option Group # 1-20 - default 0
P363E Zone 23 option Group # 1-20 - default 0 P395E Zone 55 option Group # 1-20 - default 0
P364E Zone 24 option Group # 1-20 - default 0 P396E Zone 56 option Group # 1-20 - default 0
P365E Zone 25 option Group # 1-20 - default 0 P397E Zone 57 option Group # 1-20 - default 0
P366E Zone 26 option Group # 1-20 - default 0 P398E Zone 58 option Group # 1-20 - default 0
P367E Zone 27 option Group # 1-20 - default 0 P399E Zone 59 option Group # 1-20 - default 0
P368E Zone 28 option Group # 1-20 - default 0 P400E Zone 60 option Group # 1-20 - default 0
P369E Zone 29 option Group # 1-20 - default 0 P401E Zone 61 option Group # 1-20 - default 0
P370E Zone 30 option Group # 1-20 - default 0 P402E Zone 62 option Group # 1-20 - default 0
P371E Zone 31 option Group # 1-20 - default 0 P403E Zone 63 option Group # 1-20 - default 0